Surgical Robotics Competition
Team Moonshot · AdvaMed MedTech Conference
Computer vision and simulated robotic endoscope control for hip arthroscopy — not a clinically deployed medical device.
- Period
- October 2026
- My role
- Biomedical Engineer
- Status
- Project status pending confirmation
My Contributions
- Trained RF-DETR Small instance segmentation using Roboflow.
- Used 384 × 384 inputs with training-only rotation, brightness and blur augmentation.
- Evaluated held-out test images; reported 58.6% mAP@50.
- Registered a 3D hip model to simulated endoscopic images using Forge and verified landmarks.
- Tuned image-based feedback with target-position and apparent-size tolerances for viewing-angle and insertion-depth correction.
Engineering Evidence
Artifacts pendingSegmentation examples
Not yet supplied
Evaluation report
Not yet supplied
Registration screenshots
Not yet supplied
Simulated control demonstration
Not yet supplied
Project repository not supplied.
GitHub profileEngineering Problem
Investigate how anatomical image understanding and visual feedback can support endoscope positioning in a simulated hip arthroscopy environment.
Constraints & Requirements
The control environment is simulated, not a clinically deployed medical device.
Image inputs are 384 × 384; rotation, brightness and blur augmentation are restricted to training images, separate from held-out evaluation.
System Architecture
RF-DETR Small provides instance segmentation. Forge supports registration of a 3D hip model to simulated endoscopic imagery. Image-based feedback guides simulated viewing-angle and insertion-depth adjustments.
Engineering Decisions & Tradeoffs
Segmentation, anatomical registration and feedback tuning address different stages of the perception/control workflow. Training augmentation must remain separate from held-out evaluation to avoid overstating generalization.
Alternative approaches, selection rationale and quantified tradeoff comparisons have not yet been supplied.
Testing & Verification
Held-out images were used for segmentation evaluation, with a reported 58.6% mAP@50 on the evaluated dataset. Anatomical registration was checked against identifiable landmarks. No clinical validation is claimed.
Results & Lessons
The competition linked perception, 3D alignment and simulated control. The reported segmentation result is dataset-specific; this was a simulated robotics project, not a clinically deployed device.
Reported 58.6% mAP@50 on the evaluated dataset; 384 × 384 image inputs.